This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

AMP’s first CIAT chiller installation supports world renowned cancer research at Queen Mary College

16 June 2016

The first CIAT chiller project supplied by Amp Air has been successfully completed at the John Vane Science Centre, part of Queen Mary’s Charterhouse campus, near the Barbican in central London.

The high performance, high efficiency AquaCIAT 2 Evolution chiller was installed by Basildon-based Hawkes Refrigeration Engineers as part of a major replacement and upgrade of the building’s air conditioning system.

It had previously relied on an ageing split system, using a water chiller linked to remote condensing units.

Toshiba distributor AMP was recently also appointed a distributor for CIAT following the global takeover of the France-based manufacturer by United Technologies, parent of Toshiba.

The packaged air-cooled CIAT chiller, with a capacity of 141kW of cooling, is equipped with optional inverter-controlled variable speed pumps for improved efficiency, delivering an EER of 3.09 and SEER of 4.06.

Given the sensitive research environment, the chiller is equipped with enhanced acoustic insulation in order to minimise noise in the vicinity of the installation. The R410A-based system running on Scroll compressors is designed to allow for future expansion as part of a staged replacement process.

This includes the use of 6in diam chilled water pipework and a 10in low loss header to permit the addition of up to three further Toshiba/Ciat chillers, one of which would be on standby.

The chiller was craned onto its new galvanised steel framework base at ground level alongside the building, under the project management of Hawkes Refrigeration.

Technical support staff from CIAT attended the commissioning and worked alongside engineers from Hawkes Refrigeration and Queen Mary College in the successful commissioning process.

Mark Parkin and Barry Hawkes, senior engineer and director of Hawkes Refrigeration who headed up the project, said: “This was the first CIAT chiller installation we have carried out. In discussion with the customer, we decided that as CIAT was now part of the Toshiba offering through AMP, we felt confident of the quality and technical support behind the product. Commissioning was relatively straightforward and we were pleased to have the technical support of CIAT and AMP staff on site.”

Ron Hodgson, building services project manager at Queen Mary College, said: “The project went extremely well and is now up and running trouble-free. We anticipate a mammoth return in terms of reduced running costs over the next few years.”

For more details, call AMP on 01707 378 670, or visit www.ampair.co.uk


Print this page | E-mail this page

MOST VIEWED...


Article image Why the Law Says You Need a Nappy Bin Disposal Service

At home, parents are used to disposing of their babies’ used nappies the same way they do any other domestic waste - bagging it up and sticking it in the rubbish for general collection.Full Story...

Article image Importance of compliance further confirmed by recent asbestos cases

Two incidents involving asbestos in buildings have further emphasised the need for vigilance in all areas of the FM sector to provide protection for building users and avoid the potentially damaging results.Full Story...

Britannia Hotel Group Fly the Nilfisk Flag

Finalists announced for the PFM Partnership Awards 2018

PTSG installs lightning protection at Faraday's former place of work

http://www.fsifm.comhttps://www.abm.co.uk/https://www.emergencyuk.com/pfmb18